Home > ELECTRICAL > ROUGH ELECTRICAL > LOAD CENTERS > LUG LOAD CENTERS - INDOOR > 125 AMP
Sort By:
Page of 1
Eaton BR48L125FP Load Center Eaton BR48L125SP Load Center Siemens E0408ML1125SU Load Center
Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Cable Size: 14 to 1/0 AWG, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Flush Mounting Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kA, Cable Size: 14 to 1/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Surface Mounting, Metal Code-gauge steel enclosure. Single phase, 3-wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 V. 10,000 AIR. One piece plated aluminum bus bar. 100% circuit breaker twist outs. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 A maximum) is back-fed in a branch position and used with main breaker retainer clip No MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 deg for bottom feed. Gray enamel finish. 6-5/8 in x 12-5/8 in x 3-1/2 in. UL listed, complies fully with NEC and UL requirements for Class CTL.
Eaton BR612L125SP Load Center PowerMark Gold TLM612FCUD Standard Convertible Load Center PowerMark Gold TL412C Standard Load Center
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality.
Eaton BR612L125FDP Load Center Eaton BR816L125FP Load Center Eaton BR816L125SDP Load Center
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
PowerMark Gold TLM812FCUD Standard Convertible Load Center Square D HOM816L125PC Homeline Main Lug Load Center LOAD CENTR 125A 8SP 16C INDOOR
PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Main lug indoor load center. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL listed. PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality.
PowerMark Gold TLM1212CCU Standard Convertible Load Center Siemens E0816ML1125S Load Center BRLC 125A 12/24CR AL BUS/WGB
PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. Code-gauge steel enclosure. Single phase, 3-wire, solid neutral, 8 spaces and 16 circuits maximum 1-pole, 4 QP breakers maximum 2-pole, 120/240 V. 10,000 AIR. One piece plated aluminum bus bar. 100% circuit breaker twist outs. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 A maximum) is back-fed in branch position and used with main breaker retainer clip No MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 deg for bottom feed. Gray enamel finish. 12-3/8 in x 14-3/4 in x 3-7/8 in. UL listed, complies fully with NEC and UL requirements for Class CTL. Eaton Load Center, 120/240 VAC, 125 A, Number of Phases: 1, Number of Spaces: 12, Number of Poles: 24, Number of Circuits: 24, Breaker/Load Center Type: Main Lug, Plug-On Neutral, Type BR, Interrupt Rating: 10 kAIC, Cable Size: #6 to 2/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Flush, Surface Mounting, Metal, Includes: Cover
LOAD CENTER 1PH 120/240V 125A Square D HOM2040L125PC Homeline Main Lug Load Center Square D QO124L125PGC QO Main Lug Load Center
SN Series load center is the smart choice when value and quick installation are of the highest priority. The SN Series load centers include labor saving features such as the ability to accept plug-on neutral breakers, patented Insta-wire and mounting trim tabs. These exclusive features make the SN Series load center the best load center for the value minded contractor. Main lug indoor load center. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL listed. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options.
BRLC 125A 20/40CR AL BUS/WGB  LOAD CENTR 125A 12SPACE 24CIR
Eaton Load Center, 240 V, 125 A, Number of Spaces: 20, Number of Poles: 1, Number of Circuits: 40, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Plug Mounting, Metal, Includes: Cover PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality.