Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - ARC FAULT
Sort By:
Page of 1
MES Q120AFC Arc Fault Combination Miniature Circuit Breaker HomeLine HOM120CAFIC Arc Fault Combination Circuit Breaker BREAKER CIRC ARCFAULT 120V 15A
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V. Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. Siemens Circuit Breaker, AFCI, Combination, Low Voltage, 120 V, 15 A, 1 Pole, 10 kA Interrupt, QAF2N Frame, Lug Terminal, Plug Mounting, Suitable for: Plug-On Neutral Load Center
MES Q115AFC Arc Fault Combination Miniature Circuit Breaker GE THQL Arc Fault Combination Circuit Breaker GE THQL Arc Fault Combination Circuit Breaker
Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V. Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker. Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker.
HomeLine HOM115PCAFIC CAFCI Miniature Standard Circuit Breaker HomeLine HOM120PCAFIC CAFCI Miniature Standard Circuit Breaker BREAKER CIRC ARCFAULT 120V 20A
Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Siemens Circuit Breaker, AFCI, Combination, Low Voltage, 120 V, 20 A, 1 Pole, 10 kA Interrupt, QAF2N Frame, Lug Terminal, Plug Mounting, Suitable for: Plug-On Neutral Load Center
HomeLine HOM115CAFIC Arc Fault Combination Circuit Breaker Eaton BR120CAFA Type BR Arc Fault Combination Circuit Breaker BREAKER CMB AFCI 1P 15A 10KAIC
Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. Cutler-Hammer Circuit Breaker, Type BR, 120 VAC, 20 A, 1 ph, 1 Pole, 10,000 A Interrupt, Instantaneous, Long Time Trip, 14 to 4 AWG Wire, Plug Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/8 in H, Suitable for: Type BR Load Center Eaton Circuit Breaker, Type BR, 120/240 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type BR Loadcenters
BREAKER CMB AFCI 1P 20A 10KAIC Eaton BR115CAFA Type BR Arc Fault Combination Circuit Breaker HomeLine HOM115PDFC CAFCI/GFCI Miniature Circuit Breaker
Eaton Circuit Breaker, Type BR, 120/240 V, 20 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Instantaneous, Long Time, Wire Size: 14 to 8 AWG, Pigtail Mounting, Dimensions: 6 in L x 3-1/2 in W x 1-1/4 in H, Suitable for: EATON Type BR Loadcenters Eaton Circuit Breaker, Type BR Combination AFCI, 120 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kAIC, Wire Size: 14 to 8/Aluminum AWG, Plug Mounting, Dimensions: 1.1 in H x 1 in W x 2.56 in D, Suitable for: Type BR Loadcenters Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit.
HomeLine HOM120PDFC CAFCI/GFCI Miniature Circuit Breaker HomeLine HOM115DFC CAFCI/GFCI Miniature Circuit Breaker HomeLine HOM120DFC CAFCI/GFCI Miniature Circuit Breaker
Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit.
BREAKER AFCI/GFCI 1P 15A      BREAKER AFCI/GFCI 1P 20A      BREAKER CIRC DL FUNC 120V 15A
Siemens Circuit Breaker, AFCI, GFCI, 120 V, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Instantaneous, Non-Interchangeable Trip, Trip Sensitivity: 5 mA, 12 to 8, 14 to 8 AWG Wire, Lug Terminal, Plug Mounting, Black, Dimensions: 3 in W x 1 in D x 4-1/2 in H Siemens Circuit Breaker, AFCI, GFCI, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Instantaneous, Non-Interchangeable Trip, Trip Sensitivity: 5 mA, 12 to 8, 14 to 8 AWG Wire, Lug Terminal, Plug Mounting, Black, Dimensions: 3 in W x 1 in D x 4-1/2 in H Siemens Circuit Breaker, AFCI, GFCI, Low Voltage, 120 V, 15 A, 1 Pole, 10 kA Interrupt, QFGA2N Frame, Plug Mounting, 40 deg C Operating, Suitable for: Plug-On Neutral Load Center
BREAKER CIRC DL FUNC 120V 20A Square D QO120CAFIC Type QO Arc Fault Combination Circuit Breaker Square D QO115PCAFIC CAFCI Miniature Standard Circuit Breaker
Siemens Circuit Breaker, AFCI, GFCI, Low Voltage, 120 V, 20 A, 1 Pole, 10 kA Interrupt, QFGA2N Frame, Plug Mounting, 40 deg C Operating, Suitable for: Plug-On Neutral Load Center Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded. Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit.
Square D QO120PCAFIC CAFCI Miniature Standard Circuit Breaker Square D QO115DFC CAFCI/GFCI Miniature Standard Circuit Breaker BREAKER 15A1P 120V DUAL FUNCTN
Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. GE Circuit Breaker, AFCI, Dual Function, GFCI, 120/240 VAC, 15 A, 1 ph, 1 Pole, Plug Mounting, Dimensions: 3.3 in H x 1 in W x 3.3 in D
BREAKER 20A1P 120V DUAL FUNCTN Square D QO115CAFIC Type QO Arc Fault Combination Circuit Breaker Square D QO115PDFC CAFCI/GFCI Miniature Standard Circuit Breaker
GE Circuit Breaker, AFCI, Dual Function, GFCI, 120/240 VAC, 20 A, 1 ph, 1 Pole, Plug Mounting, Dimensions: 3.3 in H x 1 in W x 3.3 in D Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded. Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit.
Square D QO120DFC CAFCI/GFCI Miniature Standard Circuit Breaker Square D QO120PDFC CAFCI/GFCI Miniature Standard Circuit Breaker BREAKER 1P 15A AFGF DUAL FUNC
Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Combination arc fault protection and Ground Fault protection (class A) in a single device. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. Eaton Circuit Breaker, BR, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14/4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H
BREAKER 1P 20A AFGF DUAL FUNC BRKR DUAL AF/GF 1P 15A PLG NEU BREAKER DUAL AF/GF 1P 20A
Cutler-Hammer Circuit Breaker, BR, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 4 AWG Wire, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H Eaton Circuit Breaker, AFCI, BR, GFCI, 120 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H Eaton Circuit Breaker, AFCI, BR, GFCI, 120 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 4 AWG, Plug Mounting, Dimensions: 2.9 in L x 2.9 in W x 0.9 in H
BREAKER CH AFCI 20A PON 10KAIC BREAKER CH AFCI 15A PON 10KAIC Eaton CHFCA120 Type CH Arc Fault Circuit Breaker
Eaton Circuit Breaker, AFCI, CH, 120/240 VAC, 20 A, Number of Poles: 1, Interrupt Rating: 10 kA, Plug Mounting, Dimensions: 4-1/2 in L x 3/4 in W x 3-1/4 in H Eaton Circuit Interrupter, AFCI, Type CH, 120/240 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kAIC, Trip Type: Common, Plug Mounting, Dimensions: 3.5 in L x 6.1 in W x 1.2 in H The National Electrical code requires all circuits feeding dwelling areas in residential structures to be protected by combination type arc fault circuit interrupters. Eaton's type CH (3/4 in) combination AFCI is available in 15 and 20 A configurations. Eaton has also included a diagnostic LED as a standard feature in the CH AFCI which indicates the most recent trip code to assist in troubleshooting.
Eaton CHFCA115 Type CH Arc Fault Circuit Breaker
Eaton Circuit Breaker, AFCI, CH, 120/240 VAC, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Pigtail Mounting, Dimensions: 4.5 in L x 0.75 in W x 1.2 in H